• Lieferung in 1 - 2 Tagen
  • 100 Tage kostenfreie Rückgabe
  • Versand aus Deutschland
  • Wir liefern Werkzeug seit 2015
  • +1 Mio. Bestellungen

Description

Scope of Delivery:
- 1x BENNING installation tester for testing electrical systems
- Installation tester, carrying case, PC software, USB/RS-232 cable, switchable commander test probe, test cable with earthing contact plug, universal 3-wire test lead (L = 1.5 m), 3 x test probes/crocodile clips, charger with 6 rechargeable NiMH batteries (type AA), calibration certificate Optional accessories (not included in the scope of delivery): Earthing set, item no. 4000 828 913 for earthing measurements via 3-wire measuring method, consisting of 2 earth spikes and 3 test leads (2 x L = 20 m, 1 x L = 4.5 m) AC current clamp adapter BENNING CC 3, item no. 4000 828 918 Alternating current 1 A - 40 A AC/DC (300 A AC/DC), output 10 mV/ 1 A. Clamp opening max. 25 mm, measuring category CAT III 600 V. incl. test leads, bag, battery (1x type block battery), replacement battery see art. no. 4000 901 814

Product Description:
suitable for electrical engineering, industry (safety tests on electrical systems up to 1000 V), initial commissioning, repeat testing, troubleshooting, logging, photovoltaics - multifunctional installation tester for testing electrical systems in accordance with DIN VDE 0100-600 (IEC 60364-6) and DIN VDE 0105-100 (EN 50110) - incl. testing of RCD/ RCD circuit breakers type B/ B+ (all-current sensitive) and type AC, A, F (mixed frequencies) Measurements: Low-impedance resistance (200 mA with polarity reversal), continuity (7 mA), insulation resistance (50 V/ 100 V/ 250 V/ 500 V/ 1000 V) - Line impedance (L-N/ L) with voltage drop and short-circuit current - Loop impedance (L-PE) without RCD tripping and short-circuit current - Testing of RCDs standard and delayed (S) (type AC, A, F, B, B+ with AUTO test, touch voltage, tripping time and tripping current (ramp)) - TRUE RMS voltage - frequency, rotating field, first fault leakage current in the IT network Measurements via optional accessories: Earthing via 3-wire method with BENNING earthing set (044113), item no. 4000 828 913, TRUE RMS current via current clamp adapter BENNING CC 1 (044037) - BENNING CC 3 (044038), item no. 4000 828 918 Special product benefits: Measured value memory across 4 levels (object, block, fuse, measuring point) - Upload of system structures, Download of measured values - Integrated real-time clock (measured value with date/time) - Bidirectional interfaces (USB/RS 232) - Clear good/bad indication via green/red LED on the test device and on switchable commander test probe - Commander test probe with TEST and MEMORY button and bright LEDConnection for barcode scanner to identify the measuring point and rename the memory location - Graphic display with backlight - Help function with connection diagram - Online voltage monitor - Battery charging function integrated in the device - PC software BENNING PC-Win IT 130: Creation and transfer (upload) of system structures to the BENNING IT 130 for efficient repeat testing - Measured value download and logging (test report, ZVEH test report)

Technical Data:
- Application: for testing electrical systems
- Brand: BENNINGNote on the disposal of batteries and accumulators Since we sell batteries and accumulators or devices containing batteries and accumulators, we are obliged under the Battery Act (BattG) to draw your attention to the following: The symbol of the crossed-out dustbin on batteries or accumulators means that they must not be disposed of with household waste after use. If batteries or accumulators contain mercury, cadmium or lead, you will find the respective chemical symbol (Hg, Cd or Pb) below the symbol of the crossed-out dustbin. Every user of batteries or accumulators is legally obliged to return old batteries and accumulators. You can do this free of charge at a retail outlet or other collection point in your area. You can obtain the addresses of suitable collection centres in your area from your city or local authority. For batteries that contain more than 0.0005 per cent mercury by mass, more than 0.002 per cent cadmium by mass or more than 0.004 per cent lead by mass, the chemical designations of the pollutant used can be found under the waste bin symbol. The chemical designations have the following meaning: Pb: Battery contains lead Cd: Battery contains cadmium Hg: Battery contains mercuryFor commercial use, please observe the building regulations!

For commercial use, please observe the building regulations!

Product form

Benning installation tester IT 130 ( 4000828919 ) for testing electrical systems

    SKU: 141615  EAN: 4014651441033  Condition: New
    €2.107,61
    Incl. VAT
    Pay in 3 instalments
    Buy now, pay later
    Buying direct is cheaper for you – find out why

    Price comparison portals and search engines charge high fees on every purchase – often over 20% of the selling price. These costs are always passed on to customers. We do things differently: instead of spending advertising budgets on large platforms, we invest in fair prices, BROpoints, gifts and exclusive best-price deals you'll only find directly with us. No middlemen. No markups. Direct for you.

    In Stock FREE Delivery  by approx. Tue, 06/16/2026

      100 Tage kostenfreie Retoure 100 days of free returns
      +2107 BROpoints
      • American Express
      • Apple Pay
      • Google Pay
      • PayPal
      • Klarna
      • Mastercard
      • +12 more

      Top Picks

        Ergänzende Artikel

        Auch interessant

        Versand (Dinotech e.K.) & GPSR

        Versand & Rechnung durch: Dinotech e.K.

        Responsible person for the EU (GPSR) Economic operator established in the EU who ensures that the product complies with the required regulations.
        • info@benning.de
        • +492871930
        • Germany
        • 46397 Bocholt
        • Münsterstr. 135-137
        • Benning Elektrotechnik und Elektronik GmbH & Co. KG

        Description

        Scope of Delivery:
        - 1x BENNING installation tester for testing electrical systems
        - Installation tester, carrying case, PC software, USB/RS-232 cable, switchable commander test probe, test cable with earthing contact plug, universal 3-wire test lead (L = 1.5 m), 3 x test probes/crocodile clips, charger with 6 rechargeable NiMH batteries (type AA), calibration certificate Optional accessories (not included in the scope of delivery): Earthing set, item no. 4000 828 913 for earthing measurements via 3-wire measuring method, consisting of 2 earth spikes and 3 test leads (2 x L = 20 m, 1 x L = 4.5 m) AC current clamp adapter BENNING CC 3, item no. 4000 828 918 Alternating current 1 A - 40 A AC/DC (300 A AC/DC), output 10 mV/ 1 A. Clamp opening max. 25 mm, measuring category CAT III 600 V. incl. test leads, bag, battery (1x type block battery), replacement battery see art. no. 4000 901 814

        Product Description:
        suitable for electrical engineering, industry (safety tests on electrical systems up to 1000 V), initial commissioning, repeat testing, troubleshooting, logging, photovoltaics - multifunctional installation tester for testing electrical systems in accordance with DIN VDE 0100-600 (IEC 60364-6) and DIN VDE 0105-100 (EN 50110) - incl. testing of RCD/ RCD circuit breakers type B/ B+ (all-current sensitive) and type AC, A, F (mixed frequencies) Measurements: Low-impedance resistance (200 mA with polarity reversal), continuity (7 mA), insulation resistance (50 V/ 100 V/ 250 V/ 500 V/ 1000 V) - Line impedance (L-N/ L) with voltage drop and short-circuit current - Loop impedance (L-PE) without RCD tripping and short-circuit current - Testing of RCDs standard and delayed (S) (type AC, A, F, B, B+ with AUTO test, touch voltage, tripping time and tripping current (ramp)) - TRUE RMS voltage - frequency, rotating field, first fault leakage current in the IT network Measurements via optional accessories: Earthing via 3-wire method with BENNING earthing set (044113), item no. 4000 828 913, TRUE RMS current via current clamp adapter BENNING CC 1 (044037) - BENNING CC 3 (044038), item no. 4000 828 918 Special product benefits: Measured value memory across 4 levels (object, block, fuse, measuring point) - Upload of system structures, Download of measured values - Integrated real-time clock (measured value with date/time) - Bidirectional interfaces (USB/RS 232) - Clear good/bad indication via green/red LED on the test device and on switchable commander test probe - Commander test probe with TEST and MEMORY button and bright LEDConnection for barcode scanner to identify the measuring point and rename the memory location - Graphic display with backlight - Help function with connection diagram - Online voltage monitor - Battery charging function integrated in the device - PC software BENNING PC-Win IT 130: Creation and transfer (upload) of system structures to the BENNING IT 130 for efficient repeat testing - Measured value download and logging (test report, ZVEH test report)

        Technical Data:
        - Application: for testing electrical systems
        - Brand: BENNINGNote on the disposal of batteries and accumulators Since we sell batteries and accumulators or devices containing batteries and accumulators, we are obliged under the Battery Act (BattG) to draw your attention to the following: The symbol of the crossed-out dustbin on batteries or accumulators means that they must not be disposed of with household waste after use. If batteries or accumulators contain mercury, cadmium or lead, you will find the respective chemical symbol (Hg, Cd or Pb) below the symbol of the crossed-out dustbin. Every user of batteries or accumulators is legally obliged to return old batteries and accumulators. You can do this free of charge at a retail outlet or other collection point in your area. You can obtain the addresses of suitable collection centres in your area from your city or local authority. For batteries that contain more than 0.0005 per cent mercury by mass, more than 0.002 per cent cadmium by mass or more than 0.004 per cent lead by mass, the chemical designations of the pollutant used can be found under the waste bin symbol. The chemical designations have the following meaning: Pb: Battery contains lead Cd: Battery contains cadmium Hg: Battery contains mercuryFor commercial use, please observe the building regulations!

        For commercial use, please observe the building regulations!

        Passendes zum Artikel

        iBasierend auf deinen Interessen

        Mehr für dich

        iBasierend auf deinen Interessen

        Ähnliche Produkte anderer Hersteller

        iBasierend auf deinen Interessen

        Passende Alternativen

        iBasierend auf deinen Interessen

        Warum Kunden uns vertrauen

        Tausende Handwerker und Heimwerker kaufen regelmäßig bei uns ein. Ihre Erfahrungen und Bewertungen helfen dir, die richtige Entscheidung zu treffen.

        • Über 1 Mio. Bestellungen seit 2021 📦
        • Versand aus Deutschland 🇩🇪
        • 100 Tage kostenfreie Retoure 🔙

        Log in

        Forgot your password?

        Don't have an account yet?
        Create account